Charging Module XEH-40K-TX-01
- Product Description
-
This is an efficient and high power density AC-DC charging module. The charging module adopts an isolated CAN communication interface and communicates with the monitoring module using the CAN communication protocol. Through system monitoring, the output voltage mode of the charging module can be set, and functions such as current limiting and module on/off can be achieved. The DC charging module, which adopts patented circuit design and innovative technology, has the advantages of wide voltage range, high efficiency, high power factor, high power density, minimal electromagnetic radiation and interference, high protection performance, and high reliability. It meets the fast charging needs of various electric vehicles, has significant energy-saving and environmental protection effects, and has reached the international leading level. It is applied in DC charging stations for low-speed electric vehicles, passenger electric vehicles, electric logistics vehicles, electric minibuses, electric buses, electric forklifts, electric tractor charging equipment, high-voltage electric vehicles, and super standard charging piles.
Product Parameters
Power model Input voltage range output voltage Full power output current Maximum output power XEH-40K-TX-01 260-485VAC 150-1000V DC 0-133.3A 40KW Note:The above test results were obtained under the test conditions of 100% load and 380VAc.
parameter minimum typical value maximum remark input Input voltage range 260VAC 380VAC 485VAC Input frequency range 45Hz 50Hz 65Hz power factor - 0.98 - 380VAC full load Total Harmonic Distortion (THD) - 5% - 380VAC efficiency - 95% - 380VACfull load, thermal steady state Input maximum impulse current ≤ Maximum input current 120% output current stability accuracy ±1% voltage regulation accuracy ±0.5% Current balancing accuracy ±5% Over 10% rated load, 380VAC High voltage mode Output voltage range 200V-1000V 380VAC full load Rated output voltage 1000V output current 40A Range of current limiting regulation 0.5A≤I≤80A Low voltage mode Output voltage range 150V-500V 380VAC full load Rated output voltage 500v output current 80A Range of current limiting regulation 0.5A≤I≤133.3A Start time: Cold start 3s st≤8s 380VAC, Full load, at room temperature Fan noise <65dB (1 m away from the device) CAN communication Maximum of 60 Ripple coefficient of output voltage ≤1% protect short circuit protection After short-circuit protection, the module has no output and automatically restarts Can be manually restored, with four short circuit locking modes Output overvoltage protection point 1050V±10V Can be manually restored, four times overvoltage lock mode over-temperature protection Automatically protect when the detected temperature reaches the preset value Shut down; After recovery, the module is in standby mode and requires a command to power it on Input Overvoltage Protection Capable of (ensuring no protection within+20% range), with hysteresis Shut down; After recovery, the module is in standby mode and requires a command to power it on Input undervoltage protection Capable of (ensuring no protection within -20% range), with hysteresis Shut down; After recovery, the module is in standby mode and requires a command to power it on Input phase loss protection The input phase loss module will automatically shut down for protection Shut down; After recovery, the module is in standby mode and requires a command to power it on Fan malfunction alarm Module fan malfunction: such as stopping rotation Shut down; Red light on, report fault fan control Control the fan speed together based on the ambient temperature and output current Automatic stepless speed regulation Note: * Four times overvoltage lock mode
After overvoltage protection, if the module has no output, it will automatically restart within 5 seconds. If overvoltage occurs again after four restarts within 5 minutes, the module will lock and stop outputting, and will not restart again until manually powered off to restore.
*Four time short circuit locking mode
After short-circuit protection, if the module has no output, it will automatically restart within 5 seconds. If the short circuit occurs again after four restarts within 5 minutes, the module will lock and stop outputting, and will not restart again until manually powered off to restore.environment ambient temperature -40℃ - 70℃ Reduced usage above 55 ℃ Storage temperature -40℃ - 85℃ Humidity 5% -90%, no condensation Atmospheric pressure at high altitude 79kPa ~ 106kPa; Altitude<2000m; for altitudes above 2000m, consideration should be given to downgrading usage cooling fan Smart Air Cooling Protection level IP20 Safety regulations and electromagnetic compatibility Dielectric withstand voltage strength I/P-O/P:2500VAC;I/P-GND:2500VAC;O/P-GND:2500VAC;Leakage current ≤ 10mA insulation resistance I/P-O/P,I/P-GND:>100M Ohms/1000VDC/25℃/70%RH grounding resistance ≤0.1Ω,25A,60s Contact current ≤3.5mA,IEC60598-1;380Vac/50Hz, China NBT 33008.1 NBT 33001 GB/T 17626.2 GB/T 17626.3 GB/T 17626.4 GB/T 17626.5 GB/T 17626.11 GB 9254-2008 North America UL2202 UL2231 European Union IEC61851 IEC60664 other MTBF 120K hrs 380VAC, Environmental temperature 25 ℃, 100% load (MIL-HDBK-217F) Dimensions (W * D * H) 300×437×84mm(Width × Depth × Height) weight ≤15kg Note: All performance parameters are typical values measured under input voltage of 380VAc and temperature of 25 ° C, unless otherwise specified.
The power supply meets EMI standards, but due to the impact of the entire device on EMI performance, the terminal equipment manufacturer needs to reconfirm the EMI of the entire device.Physical Structure