  • UXR100040 is a charging power module developed to address the pain points of the charging pile industry. It has two outstanding advantages in the industry: ultra-high full load operating temperature and ultra wide constant power range; The main features of this module include high reliability, high efficiency, high power factor, high power density, wide output voltage range, low noise, low standby power consumption, and good EMC performance.

    Excellent Performance Advantages

    1.The charging station is an outdoor application product, and it is normal for the air inlet temperature to be between 50-60 ° C in summer. The thermal problem of the charging module is very prominent, and the vast majority of charging modules in the industry cannot withstand high temperature environments (usually 50 ° C or 55 ° C full power), so they can only be used with power limiting and derating, which greatly reduces the charging speed!

    2.In order to improve the range of electric vehicles, increasing the capacity of power batteries and improving the voltage of the vehicle's power batteries is the trend of the future. The mainstream DC module output voltage in the market is currently up to 750V, and the maximum output power is 20KW. UXR100040 has an output voltage range of 100-1000V, and can achieve a constant power output of 40KW in the full range of 300-1000V. Its ultra wide output voltage range and ultra wide output constant power range are at the forefront of the industry.

    3.UXR100040 is capable of full power output at 60 ° C, effectively ensuring charging speed in high-temperature environments

    4.UXR100040's ultra wide output voltage range and ultra-high output power are suitable for charging various electric vehicles and greatly improve charging speed

    Main Features

    • Ultra wide output voltage range, 100~1000Vdc, suitable for various vehicle models;

    • Ultra high output power, output voltage between 300V~1000V, constant power output of 40KW;

    • Wide operating temperature range at full power, -40 ° C~60 ° C;

    • Full load efficiency higher than 95.5%, high efficiency across the entire operating range, and more energy-efficient;

    • Ultra low noise, enhancing user charging experience;

    • Low voltage area current does not retract, charging speed is faster;

    • The module is equipped with a residual pressure relief circuit, which reduces system costs and improves system reliability;

    • Passed CE certification and met RoHS requirements;

    Product Parameters

    name parameter
    Basic indicators size 85mm (height) x 360mm (width) x 459mm (depth)
    weight ≤20kg
    Efficiency (full load) >95.5%
    standby power consumption <13W
    cooling method Forced air cooling
    communication method CAN bus
    Parallel unit quantity ≤ 60 pieces
    indicator light Green: Normal operation Yellow: Protection alarm Red: Fault alarm
    Input characteristics input voltage 285Vac~475Vac, Three phase+protective ground
    input current <80A
    grid frequency 45Hz~65Hz
    power factor ≥0.99
    ITHD ≤5%
    output characteristics output power 40kW @ output voltage ≥ 300Vdc
    voltage range 100-1000Vdc, Default value: 200Vdc
    current range 0A~133.3A
    voltage regulation accuracy ≤±0.5%
    current stability accuracy ≤±1%
    Unequal current distribution ≤±3%
    Ripple peak to peak value ≤1%
    environmental conditions Operating Temperature -40 ℃~+75 ℃, no derating at 60 ℃
    Storage temperature - 40℃~ + 75℃
    relative humidity ≤95%RH, No condensation
    altitude No need to reduce the rating for distances ≤ 2000m; >2000m, For every 100 meters increase, the working temperature decreases by 1 ℃
    MTBF >500000 hours
    Alarm and protection Input over/under voltage Shutdown can automatically restore
    output overvoltage Shutdown requires manual recovery
    Overcurrent and short circuit Shutdown requires manual recovery
    overtemperature Shutdown can automatically restore

    Output external characteristic curve

    Output voltage (Vdc) and output current (A)

     

    Temperature limited power curve

    Output power (%) Environmental temperature (℃)

    AC input power limit curve

    Output power (kW) AC input voltage (V)

Key words:

Get A Quote

Note: Please leave your contact information, our professionals will contact you as soon as possible!

Submit Now